 Featured CapsuleGuard™ I/A Handpiece Millennium®/Other Systems 45° 85910S This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges for reduced risk of capsule rupture. The silicone tip design facilitates cortex removal, capsule polishing, viscoelastic removal and IOL manipulation in the capsular bag and the semi-transparent silicone sleeve provides superior visualization. A fully assembled single-use design is provided for safety, consistency More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Curved 85913S This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edg More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Straight 85912S This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured CapsuleGuard™ I/A Handpiece Stellaris® System 45° 85910ST This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Curved 85913ST This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges fo More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Straight 85912ST This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured Jensen Capsule Polisher E0511 ED 27 gauge cannula with gently curved shaft. Olive tip with lower half electro-dusted. Polished finish. Overall length: 27mm, 1.1 inches. More Details >
Kratz Capsule Scraper Electro-Dusted Tip E0508 ED Electro-dusted tip. 23 gauge cannula with 1mm angled tip. Polished finish. Overall length: 21mm, 0.8 inches. More Details >
 Featured Kratz Capsule Scraper Sandblasted Tip E0508 Sandblasted tip. 23 gauge cannula with 1mm angled tip. Polished finish. Overall length: 21mm, 0.8 inches. More Details >
Pepose Micro Capsule Polisher E0525 This instrument is designed for polishing the underside of the anterior capsular leaflets, which is an essential step prior to placement of an accommodating IOL. The polishing tips are small enough to More Details >
Simcoe Capsule Scrubber E4969 CS 23 gauge cannula. Curved shaft with sandblasted 2mm distal tip. Polished finish. Overall length: 13mm, 0.5 inches. More Details >
Simcoe Posterior Capsule Polisher E0558 PS 23 gauge cannula with sandblasted tip. Shaft angled 45°, 14mm from tip to bend. Polished finish. Overall length: 16mm, 0.6 inches. More Details >
Simcoe Posterior Capsule Scrubber E4969 R 23 gauge cannula with curved shaft. Reverse aperture. Polished finish. Overall length: 13mm, 0.5 inches. More Details >
Terry Scraper Irrigating E3123 Used with irrigation to stabilize the anterior chamber while gently roughening the inner stromal surface of the cornea in preparation for the graft in the DSEK procedure. Overall length: 111mm, 4.4 in More Details >
 Featured Terry Scraper Non-Irrigating E3124 Used to gently roughen the inner stromal surface of the cornea in preparation for the graft in the DSEK procedure. Overall length: 115mm, 4.5 inches. More Details >
Thornton Aspirating Capsule Polisher E4417 T Aspirating 27 gauge cannula with “U” shape permits aspiration of 12 o’clock cortex. The tip is sandblasted to act as a capsule polisher. Overall length excluding hub: 23mm, 0.9 inche More Details >
 Featured Whitman Shepherd Double-Ended Capsule Polisher E0523
This instrument is designed for removing LECs from the inner surface of the capsule. The circular ends are ideal for cleaning the equator of the ca More Details >
|