A. W. Brown Nucleus Cracker 2-800 A reverse action instrument with paddle tips to provide a solid surface to crack the nucleus. When used in a scleral tunnel, the reverse action mechanism allows increased flexibility in positioning th More Details >
 Featured Air Injection Cannula 30 Gauge E0499 30 30 gauge. Angled 45° shaft, 5mm from tip to bend with polished finish. Overall length excluding hub: 19mm, 0.75 inches. More Details >
Angled Diamond Keratome 2.5mm E0104 ACC2.5 Angled clear cornea keratome with sharp sides, tip angle 45°. For anterior chamber entrance, wound extension. J-slot blade retraction mechanism. 0.2mm blade thickness. Length from tip to mounting More Details >
Angled Diamond Keratome 3.0mm E0104 ACC3.0 Angled clear cornea keratome with sharp sides, tip angle 45°. For anterior chamber entrance, wound extension. J-slot blade retraction mechanism. 0.2mm blade thickness. Length from tip to mounting More Details >
Barrett Hydrodelineation Cannula 25 Gauge E4413 BAR This 25 gauge cannula is beveled up to provide easy insertion and injection of fluid for performing hydrodelineation of the lens nucleus. Overall length excluding hub: 20mm, 0.8 inches. More Details >
 Featured Bechert Nucleus Rotator E4937 Y shape rotator tip. Shaft angled 7mm from tip to bend. Round knurled handle with polished finish. Overall length: 121mm, 4.7 inches. More Details >
 Featured CapsuleGuard™ I/A Handpiece Millennium®/Other Systems 45° 85910S This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges for reduced risk of capsule rupture. The silicone tip design facilitates cortex removal, capsule polishing, viscoelastic removal and IOL manipulation in the capsular bag and the semi-transparent silicone sleeve provides superior visualization. A fully assembled single-use design is provided for safety, consistency More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Curved 85913S This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edg More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Straight 85912S This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured CapsuleGuard™ I/A Handpiece Stellaris® System 45° 85910ST This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Curved 85913ST This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges fo More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Straight 85912ST This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured Castroviejo Caliper E2404 Caliper measures from 0mm to 20mm in 1mm increments with scale reading on both sides. Thumbscrew holds tips apart at desired setting. Features polished finish. Overall length: 86mm, 3.4 inches. More Details >
Cystotome Irrigating 25 Gauge Formed E7113 Formed irrigating cystotome, 25 gauge, with 12.0mm curved tip. Overall length excluding hub: 16mm, 0.6 inches. Packaged sterile. Single-Use. 5/box. More Details >
 Featured Drysdale Nucleus Manipulator E0629 Flattened paddle tip with generous surface area is ideal for manipulating tissue, rotating, and cracking the nucleus. Round knurled handle. Overall length: 110mm, 4.3 inches. More Details >
Kellan Hydrodissection Cannula E4419 Gently curved 25 gauge cannula with flattened blunt tip to slip under the anterior capsular flap. Overall length excluding hub: 18mm, 0.7 inches. More Details >
 Featured Kratz Capsule Scraper Sandblasted Tip E0508 Sandblasted tip. 23 gauge cannula with 1mm angled tip. Polished finish. Overall length: 21mm, 0.8 inches. More Details >
 Featured Kratz-Barraquer Eye Speculum E4106 K Open 14mm blades. Blade spread: 18mm. Dull finish. Overall length: 41mm, 1.6 inches. More Details >
Kratz-Barraquer Eye Speculum Pediatric E4107 K Open 10mm blades. Blade spread: 19mm. Dull finish. Overall length: 35mm, 1.4 inches. More Details >
Kratz-Nichamin Speculum E4106 N Open wire style 16mm blade with a wing tip twist giving the surgeon better on-axis accessibility. Overall length: 45mm, 1.8 inches. More Details >
 Featured Kuglen Iris Hook and Lens Manipulator E0567 Designed for iris retraction and IOL manipulation. Straight shaft with 0.5mm “K” hook. Flat smooth handle with dull finish. Overall length: 117mm, 4.6 inches. More Details >
Maloney Keratometer 6-700 Cone-shaped instrument designed to reflect the microscope light in rings on the cornea to detect astigmatism. Titanium. More Details >
Microsurgical Instrument Tray 50-60 Instruments E7414 Complete with E7419 H Cannula bar and compartment for sterilization of bipolar cords, I/A accessories, etc. Anodized aluminum. Durable and lightweight with built-in protection against rust. Security l More Details >
 Featured Nichamin Hydrodissection Cannula 25 Gauge E4421 H 25 gauge. Curved cannula designed to follow the scleral tunnel incision and anterior lens capsule. The unique flattened tip allows for a better fit under the capsular leaflet. Overall length excluding More Details >
Osher Trifacet Tunnel Diamond Knife With Footplate E0108 LS Universal trifacet shaped diamond blade provides excellent control when used in a sweeping motion during scleral tunneling. The two sharp sides ensure straight tunnel incisions for lens implantation, More Details >
|