 Featured Air Injection Cannula 30 Gauge E0499 30 30 gauge. Angled 45° shaft, 5mm from tip to bend with polished finish. Overall length excluding hub: 19mm, 0.75 inches. More Details >
Aspiration Handpiece 23 Gauge 0.4mm Polishing Tip ET4750 AP23 Used to remove residual cortex after phacoemulsification. Roughened surface for polishing. Can be used through either sideport incision, thus the surgeon is able to easily reach the cortex in every qu More Details >
Aspiration Handpiece Curved MICS 1.8mm 85901S19 For use in 1.8mm biaxial microincision cataract surgery. 19 gauge, curved More Details >
Barrett Hydrodelineation Cannula 25 Gauge E4413 BAR This 25 gauge cannula is beveled up to provide easy insertion and injection of fluid for performing hydrodelineation of the lens nucleus. Overall length excluding hub: 20mm, 0.8 inches. More Details >
 Featured CapsuleGuard™ I/A Handpiece Millennium®/Other Systems 45° 85910S This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges for reduced risk of capsule rupture. The silicone tip design facilitates cortex removal, capsule polishing, viscoelastic removal and IOL manipulation in the capsular bag and the semi-transparent silicone sleeve provides superior visualization. A fully assembled single-use design is provided for safety, consistency More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Curved 85913S This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edg More Details >
CapsuleGuard™ I/A Handpiece Millennium®/Other Systems Straight 85912S This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured CapsuleGuard™ I/A Handpiece Stellaris® System 45° 85910ST This instrument features a flexible 45° tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Curved 85913ST This instrument features a flexible curved tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp edges fo More Details >
CapsuleGuard™ I/A Handpiece Stellaris® System Straight 85912ST This instrument features a flexible straight tip design for effective cortical removal. Recommended for use in a 2.2 - 2.8mm incision, the smooth irrigation and aspiration ports eliminate sharp e More Details >
 Featured Castroviejo Caliper E2404 Caliper measures from 0mm to 20mm in 1mm increments with scale reading on both sides. Thumbscrew holds tips apart at desired setting. Features polished finish. Overall length: 86mm, 3.4 inches. More Details >
Cystotome Irrigating 25 Gauge Formed E7113 Formed irrigating cystotome, 25 gauge, with 12.0mm curved tip. Overall length excluding hub: 16mm, 0.6 inches. Packaged sterile. Single-Use. 5/box. More Details >
Irrigating Handpiece 21 Gauge 0.4mm ET4750 I21 Used to remove residual cortex after phacoemulsification. Handpiece is autoclavable and maintains the anterior chamber. It has dual 0.4mm irrigating ports. Fits on male irrigation connector of the MIL More Details >
Irrigation Handpiece Curved MICS 1.8mm 85902ST19 For use in 1.8mm biaxial microincision cataract surgery. 19 gauge, curved shaft. Smooth tip. 2 lateral irrigation ports of 0.6mm. Designed to fit the Stellaris More Details >
Kellan Hydrodissection Cannula E4419 Gently curved 25 gauge cannula with flattened blunt tip to slip under the anterior capsular flap. Overall length excluding hub: 18mm, 0.7 inches. More Details >
 Featured Kratz Capsule Scraper Sandblasted Tip E0508 Sandblasted tip. 23 gauge cannula with 1mm angled tip. Polished finish. Overall length: 21mm, 0.8 inches. More Details >
 Featured Kratz-Barraquer Eye Speculum E4106 K Open 14mm blades. Blade spread: 18mm. Dull finish. Overall length: 41mm, 1.6 inches. More Details >
Kratz-Barraquer Eye Speculum Pediatric E4107 K Open 10mm blades. Blade spread: 19mm. Dull finish. Overall length: 35mm, 1.4 inches. More Details >
Kratz-Nichamin Speculum E4106 N Open wire style 16mm blade with a wing tip twist giving the surgeon better on-axis accessibility. Overall length: 45mm, 1.8 inches. More Details >
 Featured Kuglen Iris Hook and Lens Manipulator E0567 Designed for iris retraction and IOL manipulation. Straight shaft with 0.5mm “K” hook. Flat smooth handle with dull finish. Overall length: 117mm, 4.6 inches. More Details >
Maloney Keratometer 6-700 Cone-shaped instrument designed to reflect the microscope light in rings on the cornea to detect astigmatism. Titanium. More Details >
Microsurgical Instrument Tray 50-60 Instruments E7414 Complete with E7419 H Cannula bar and compartment for sterilization of bipolar cords, I/A accessories, etc. Anodized aluminum. Durable and lightweight with built-in protection against rust. Security l More Details >
Nagahara Chopper 85903ST19 For use in 1.8mm biaxial microincision cataract surgery. 19 gauge endout chopper. Designed to fit the Stellaris More Details >
 Featured Nichamin Hydrodissection Cannula 25 Gauge E4421 H 25 gauge. Curved cannula designed to follow the scleral tunnel incision and anterior lens capsule. The unique flattened tip allows for a better fit under the capsular leaflet. Overall length excluding More Details >
 Featured Sinskey Hook II Round Handle Titanium 6-250 0.18mm diameter angled tip, 10mm angled shaft. Used to mark the visual axis. Round knurled handle with dull finish. Titanium. Overall length: 119mm, 4.7 inches. More Details >
|